Home > Products > New 8-OHdG Check ELISA [ Print page ] Rev.150727
Biomarkers for DNA oxidation. oxidative stress
New 8-OHdG Check ELISA
8-oxo-dG/8-hydroxy-2'-deoxyguanosine
Suitable for assessment of oxidative stress using urine samples. For research use only.
About 8-hydroxy-2'-deoxyguanosine (8-OHdG):
8-hydroxy-2'-deoxyguanosine (8-OHdG) is a product of oxidatively damaged DNA formed by hydroxy radical, singlet oxygen and direct photodynamic action. 8-OHdG can be detected in tissue, serum, urine and other biomaterials. New 8-OHdG Check is a competitive enzyme-linked immunosorbent assay (ELISA) utilising monoclonal antibody (clone N45.1) which is highly specific for DNA damage, not cross react with RNA oxidation products such as 8-hydroxy-guanine and 8-hydroxy-guanosine. This product is suitable for detection of 8-OHdG in urine and other biomaterials from human and animals.
This product is a 8-OHdG ELISA kit utilizing anti 8-OHdG monoclonal antibody (clone N45.1) which is highly specific for 8-OHdG. We provide two types of 8-OHdG ELISA kits with different assay range. New 8-OHdG Check ELISA is suitable for urine and serum sample from animal and human. If you are planning to measure 8-OHdG in human serum,tissue, cultured cells, we recommend to use 'Highly Sensitive 8-OHdG Check ELISA'.
Specifications
Assay principle: Competitive ELISA (detection: 450 nm)
Specifity: Specific for 8-OHdG. Antibody have been tested to 8-OHdG analogues (guanosine(G),7-methyl-G, 6-SH-G, 8-Bromo-G, dA, dC, dT, dI, dU, dG, O6-methyl-dG,8-OHdA, guanine(Gua),O6-methyl-Gua, 8-OH-Gua, uric acid, urea, creatine, creatinine, 8-sulfhydryl-G, 8-OH-G).
Measuring range: 0.5 to 200 ng/mL
Format: 96 wells (18 samples in triple assays)
Applications: Urine from human and animals.
For serum and tissue samples, Highly Sensitive 8-OHdG Check (code #KOG-HS10E) is recommended.
Storage: Store at 4 - 10°C (don't freeze).
Expiry: 12 months after the day of manufacturing.
Required but not provided: Micropipet and chip (100 micro L, 1000 micro L).
Measuring pipet (10 mL, 20 mL)/ measuring cylinders.
8 or 12-syncronous multichannel pipet and reagent tray for multichannel pipet.
Microplate reader (filter; 450 nm).
Content of this kit
8-OHdG Microtiter Plate: Precoated with 8-OHdG(12 X 8wells, split type) 1 plate
Primary Antibody: Anti 8-OHdG antibody, powder. 1 vial
Primary Antibody Solution   1 vial (6mL)
Secondary Antibody: HRP-anti mouse antibody, powder. 1 vial
Secondary Antibody Solution:   1 vial (12mL)
Chromatic Solution: 3,3',5,5'-tetramethylbenzidine 1 vial (0.25mL)
Diluting Solution: H2O2 containing buffer. 1 vial (12mL)
Washing Solution(5x):   2 vials (26mL x 2)
Reaction Terminating Solution: 1M Phosphoric acid. 1 vial (12mL)
Standard 8-OHdG Solution: Purified 8-OHdG (0.5, 2, 8, 20, 80, 200 ng/mL) 1 vial each
Plate Seal:   2 sheets
References
1) H.Kasai, P.F.Crain, Y.Kuchino, S.Nishimura,A.Ootsuyama and H.Tanooka : Formation of 8-hydroxyguaine moiety in cellular DNA by agents producing oxygen radicals and evidence for its repair. Carcinogenesis 7(11), p1849-1851 (1986)
[ 8-OHdG/8-OHG is formed by reactive oxygen radicals. ]
2) R.G.Cutler: Antioxidants and aging. Am J Clin Nutr 50,p373S-379S (1991)
[ Relationship between lifespan and antioxidants, enzymes and 8-OHdG. ]
3) S.Toyokuni, T.Tanaka, Y.Hattori, Y,Nishiyama, A.Yoshida, K.Uchida, H.Hiai, H.Ochi and T.Osawa: Quantitative immunohistochemical determination of 8-hydroxy-2'deoxyguanosine by a monoclonal antibody N45.1: Its application to ferric nitrilotriacetate-induced renal carcinogenesis model. Lab Invest 76(3), p365-374 (1997)
[ Specifity of the antibody clone N45.1.]
4) Saito S, Yamauchi H, Hasui Y, Kurashige J, Ochi H, Yoshida K: Quantitative determination of urinary 8-hydroxydeoxyguanosine (8-OH-dg) by using ELISA. Res Commun Mol Pathol Pharmacol 107(1-2),p39-44 (2000)
[ Development and assessment of 8-OHdG Check ELISA. ]
5) Nagayoshi Y, Kawano H, Hokamaki J, Miyamoto S, Kojima S, Shimomura H, Tsujita K, Sakamoto T, Yoshimura M, Ogawa H: Urinary 8-hydroxy-2'-deoxyguanosine levels increase after reperfusion in acute myocardial infarction and may predict subsequent cardiac events. Am J Cardiol. 95(4), p514-517 (2005)
[ Measurement of 8-OHdG in human urine. ]
6) Morillas-Ruiz J, Zafrilla P, Almar M, Cuevas MJ, Lopez FJ, Abellan P, Villegas JA, Gonzalez-Gallego J: The effects of an antioxidant-supplemented beverage on exercise-induced oxidative stress: results from a placebo-controlled double-blind study in cyclists. Eur J Appl Physiol 95(5-6),p543-549(2005)
[ Study about exercise, antioxidant supplements and urinary 8-OHdG. ]
7) Someya T, Kaneko K, Yamada T, Yamashiro Y: Effect of a novel free radical scavenger, edaravone, on puromycin aminonucleoside induced nephrosis in rats. Pediatr Nephrol 20(10),p1430-1434(2005)
[ Effect of antioxidants to 8-OHdG in rat urine. ]
8) Shiihara T, Kato M, Ichiyama T, Takahashi Y, Tanuma N, Miyata R, Hayasaka K: Acute encephalopathy with refractory status epilepticus: Bilateral mesial temporal and claustral lesions, associated with a peripheral marker of oxidative DNA damage. J Neurol Sci 250(1-2),p159-161(2006)
[ Measurement of 8-OHdG in human urine, serum and cerebro spinal fluid(CSF). ]
Product name Code Assay range Format Application
New 8-OHdG Check KOG-200SE 0.5-200 ng/mL 96 wells Urine and animal serum.

Made in Japan.

Related products:    Highly sensitive 8-OHdG Check ELISA    Anti 8-OHdG monoclonal antibody
Ordering Information

If you are in the U.S., please click here
to Genox Corporation (Los Angeles, CA)
.

Instruction manual Quality control Technical information
 
Application to serum Application to urine Techincal tips for ELISA
[NOTICE]: Our products are for RESEARCH USE ONLY. Not for diagnostic, medical or other use.

We are making efforts to prevent errors or mistakes on preparing web site documents, instruction manuals and products.
But even if some damage would causedby such faults, we will be exempt from responsibility.
Page top